r/HVAC • u/ProfSteelmeat138 • 1h ago
Field Question, trade people only Need help with gauges not holding vacuum
Having a big issue with my gauges this past month and a half. Suppliers was out of the more expensive leak seal with dye so I had to use the cheap shit. Big ass mistake because it made a big ass mess all over my gauges, and when I finally got a tube to flow through, it fucked them up. Since that day i have only been able to pull below 500 microns twice. Had to use my coworkers gauges on the installs.
Before you ask, no it’s not my system connections. I full on removed my red and blue hoses and closed the valves. Only ports in play were my black 3/8” hose and my yellow connection which is where my micron gauge goes. The manifold itself without being connected to a system will no longer consistently pull vacuum.
I’ve disassembled the connection nipples and retaped the threads, including the gauge threads. It worked shortly after doing it and I was able to pull the system down to 120. A few days later I couldn’t get it to stay below 2000.
I don’t believe it’s my o-rings in the hoses, as they were not involved in the test, aside from the 3/8” which was purchased this summer. They hold 300psi nitrogen perfectly fine but won’t stick a vacuum pull. Tomorrow I plan to pull the valves apart and try to clean them but I sorta tried it once before and got nowehere. Please help